Poretech

Innova BET 比表面積分析儀 Model: iBET-04P

  • Analysis stations: 4-Station, fully automated operate
  • Surface Area and Pore Size by Gas Sorption
  • Adsorption / Desorption isotherm
  • Specific surface area: BET, Langmuir
  • Meso pore size distribution: BJH, Dollimore-Heal
  • Micropore area and volume: Dubinin-Radushkevich, t-Plot method
  • Micropore distribution: MP, HK, DA, DR and t-Plot
  • Total pore volume and average pore width
  • Auto Degassing: full-automatic, 4 degassing modes are selectable
  • iBET-04P series specific surface area and pore size analyzer is a high-throughput analysis instrument that should be mainly used in mesopore and macropore nanomaterials; it has advanced technology, excellent quality, more comprehensive theoretical models, and has ultra-high Stability and repeatability; large-capacity Dewar flask, which can meet the long-term analysis of materials such as micropores of 6-2nm and avoid test failure caused by the depletion of liquid nitrogen.
  • High-throughput design: four sample analysis stations with four degassing stations can be analyzed
  • Integrated design of degassing station and analysis station, and has a completely independent vacuum system and gas line; We also use composite heating furnaces to replace uneven and fragile heating
  • The linearity of the heating rate can be adjusted, the temperature control accuracy is high, and the insulation
  • Each analysis port is equipped with an independent pressure sensor, with high analysis data
  • Adopt dynamic temperature difference calibration technology to solve the impact of liquid nitrogen volatilization on volume and improve the stability of
  • The gas line control system adopts a high-precision pressure electronic control system (PFC) with a locked high-vacuum
  • Optional embedded isothermal jacket module for gas isothermal adsorption test at 0°C-60°C.
型號 iBET-04P
Analysis ports 4
壓力傳感器 •  1000 Torr: 3 set / 5 set

•  10 Tore: 1set

Accuracy of transducer ±0.1% FS
P0 Port 1
P/P0 range 5×10-5 to 1
Surface area range 0.0005m2/g upto no upper limit
孔徑範圍 3.5Å ~ 5000Å
Min. measure pore volume < 0.001ml/g
Constant void volume system Build-in
Repeatability of surface area 1% (Based on RM)
LN2 Dewar 3.5L
Vacuum pump ability 1×10-2 Pa
Adsorbates N2, Ar, CO2, Kr, O2 any non-corrosive gas
 

 

Degassing system

•   4 ports of independent degassing station

•   4 degassing modes are selectable

•   Temp. range: Room temp. to 400

•   Vacuum ability: 1×10-2 Pa

•   Pressure Transducer: 1000 torr x 1 set

Gas Inlet Ports 2 ports
 

 

 

Test Results

•  Adsorption / desorption isotherm

•  Specific surface area: BET, Langmiur

•  Meso pore size distribution: BJH, Dollimore-Heal

•  Micropore area and volume: Dubinin- Radushkevich, t-Plot method

•  Micropore distribution: MP, HK, DR and T-Plot

•  Total pore volume and average pore width

  • Achieve best accuracy for ultra-low surface area and pore size by nitrogen adsorption.
  • Repeatability of conventional samples is better than 0.1%
  • Long-term stability for low surface area analysis is better than 1%
  • Breaking through the traditional “mesopore used instrument” and making micropore analysis by N₂ successful.